EN
CraterTime
0.0 – 10.0 s 0.1 s steps. Factory setting 1.0 s CrateFill Slope Time
Crater 4T Timer
On or OFF Factory setting is OFF ON: if 4T is selected crater lling will last
at least time that has been ad-justed by
CraterTime or as long as trigger is pressed.
OFF: if 4T is selected crater lling will last as
long as trigger is pressed.
Creep Start
10 – 99% 1% steps. OFF, CURVE
(OFF = 100%)
Factory setting is CURVE (Creep Start value
comes from Welding Curve).
StartPower
-9 ... +9 Factory setting is 0 Adjusts arc ignition
WISEROOT / WISETHIN
2T/4T
2T, 4T, MATCHLOG
or USER
Factory setting is USER =>
USER can freely choose the
switching logic
Set switching logic
HotStart
ON, OFF or USER Factory setting is USER =>
USER can freely choose is the
HotStart ON or OFF
HotStartLevel
-50 ... +100 % 1 % steps. Factory setting 40%
Hot 2T Time
0 – 9.9 s 0.1 s steps. Factory setting
1.2 s
CraterFill
ON, OFF, USER Factory setting is USER =>
USER can freely choose is the
CraterFill ON or OFF
CraterStart
10 – 250% Factory setting is 100% Set the level of the curve where the crater
lling will start.
CraterFillEnd
10 – 250%, not
higher than start
1 % steps. Factory setting 30%
CraterTime
0.0 – 10.0 s 0.1 s steps. Factory setting
1. 0 s
Crater 4T Timer
On or OFF Factory setting is OFF ON: if 4T is selected crater lling will last
at least time that has been ad-justed by
CraterTime or as long as trigger is pressed.
OFF: if 4T is selected crater lling will last as
long as trigger is pressed.
Creep Start
10 – 99% 1% steps. OFF, CURVE (OFF =
100%)
Factory setting is CURVE (Creep Start value
comes from Welding Curve).
13
FastMig Pulse 350, 450 / © Kemppi Oy / 1110