B3000 SERVICE MANUAL
60-200807-000, REV C 45
4. Gently pull OUT and UP the valve assembly.
5. Reinstall the new valve.
NOTE: When reinstalling the new valve, you MUST make sure that the “O” ring on the bottom of
the outlet tube is in place.
NOTE: The large Plastic Nut must be tight. Failure to do so will cause a leak when the hot water
feature is selected.
6. Conduct a BIT test (see appendix VII on page 85) to insure the proper function of the brewer.