350 Keysight CXG, EXG, and MXG X-Series Signal Generators Programming Guide
Creating and Downloading User–Data Files
Pattern RAM (PRAM) Data Downloads
60 bytes / 14 bytes = 4.29 file replications
The signal generator rounds this real value up to the next highest integer. In
this example, the signal generator replicates the fourteen 32–bit words (56
bytes) by a factor of 5, which makes the final file size 280 bytes. This
equates to a 70 byte file.
14 bytes x 5 = 70 bytes
70 + [(70 x 24) / 8] = 280 bytes
Or
56 bytes x 5 = 280 bytes
File size increases
by a factor of 5