Abort Commands
Abort commands cancel any pending triggered actions. They return the specified trigger system back
to the Idle state.
ABORt:ACQuire (@<chanlist>)
ABORt:ELOG (@<chanlist>)
ABORt:TRANsient (@<chanlist>)
ABORt:ACQuire and ABORt:ELOG commands require to be installed on
models N673xA. N674xA, N675xA, and N677xA.
ABORt:ACQuire - Cancels any triggered measurements. It also resets the WTG-meas bit in the
Condition Status register.
ABORt:ELOG - Stops external data logging.
ABORt:TRANsient - Cancels any triggered actions. It also resets the WTG-tran bit in the Operation
Condition Status register.
Parameter Typical Return
(none) (none)
Aborts the triggered action: ABOR:ACQ (@1)
Stops the external data log: ABOR:ELOG (@1)
Aborts the triggered action: ABOR:TRAN (@1)
l ABORt:ACQuire and ABORt:TRANsient are also executed at power-on and upon execution of the
*RST command.
l Abort:TRANsient does not turn off continuous triggers if INITiate:CONTinuous:TRANsient ON has
been programmed. In this case, the trigger system will automatically re-initiate.
5 SCPI Programming Reference
184 Keysight N6700C Operating and Service Guide