Model Differences
Feature
(l = available)
DC Power High-Performance Precision
N673xB, N674xB, N67'7xA N675xA N676xA
50 W output rating N6731B – N6736B N6751A N6761A
100 Woutput rating N6741B – N6746B N6752A N6762A
300 Woutput rating N6773A – N6777A N6753A, N6754A N6763A, N6764A
500 Woutput rating N6755A, N6756A N6765A, N6766A
Output disconnect relays Option 761 Option 761 Option 761
Output disconnect/polarity reversal relays
1
Option 760 Option 760 Option 760
Arbitrary waveform generation Option 054 Option 054
l
Autoranging output capability
l l
Voltage or current priority N6761A, N6762A
Precision voltage and current measurements
l
Low voltage and low current output range N6761A, N6762A
Low voltage and low current measurement range
l
200 microampere measurement range
2
Option 2UA
Simultaneous voltage and current measurements
l
SCPI command output list capability
3
Option 054 Option 054
l
SCPI command array readback
3
Option 054 Option 054
l
SCPI command programmable sample rate
3
Option 054 Option 054
l
SCPI command external data logging
3
Option 054 Option 054
l
Double-wide (occupies 2 channel locations) N6753A - N6756A N6763A - N6766A
Note 1 Output current is limited to 10A max. on Models N6742B and N6773A with Option 760.
Option 760 is not available on Models N6741B, N6751A, N6752A, N6761A, and N6762A.
Note 2 Option 2UA.is only available on Models N6761A and N6762A. It includes Option 761.
Note 3 Only available when using the remote interfaces; not from the front panel.
Keysight N6700C Operating and Service Guide 41