[SOURce:]ARB:SEQuence:STEP:CURRent:UDEFined:DWELl <value>{<,value>}, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:UDEFined:DWELl? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:UDEFined:DWELl <value>{<,value>}, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:UDEFined:DWELl? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:UDEFined:DWELl <value>{<,value>}, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:UDEFined:DWELl? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:UDEFined:DWELl <value>{<,value>}, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:UDEFined:DWELl? <step#>, (@<chanlist>)
Specifies the dwell time for each user-defined Arb point for Arb Sequence steps. The last value in the
sequence is the step number.
Range in seconds Dwell resolution Range in seconds Dwell resolution
All Models except N678xA Models N678xA only
0 - 0.262144 1 microsecond 0 - 0.268435 1.024 microsecond
0 - 2.62144 10 microseconds 0 - 2.68435 10.24 microsecond
0 - 26.2144 100 microseconds 0 - 26.8435 102.4 microsecond
0 - 262.144 1 millisecond 0 - 268.435 1.024 millisecond
Parameter Typical Return
0 - 262.144 (all except N678xA SMU)
0 - 268.435 (N678xA SMU only
*RST 1 point with a value of 0.001
<dwell time>
Step 0 - 99, *RST 0 (none)
Program a current dwell list: ARB:CURR:UDEF:DWEL 0.1,0.2,0.3,0.4,0.5,(@1)
Program a voltage dwell list: ARB:VOLT:UDEF:DWEL 0.1,0.2,0.3,0.4,0.5,(@1)
Program a power dwell list: ARB:POW:UDEF:DWEL 0.1,0.2,0.3,0.4,0.5,(@1)
Program a resistance dwell list: ARB:RESISTANCE:UDEF:DWEL 0.1,0.2,0.3,0.4,0.5,(@1)
Program a dwell list for step 0: ARB:SEQ:STEP:CURR:UDEF:DWEL 0.1,0.2,0.3,0.4,0.5, 0,(@1)
l At the end of the user-defined Arb, the output state of the unit depends upon the ARB:TERMin-
ate:LAST program settings.
l The order in which the values are entered determines the sequence of execution.
l To create a valid user-defined Arb, the current level, voltage level, power level, resistance level,
BOST, and dwell lists must either all be the same length, or have a length of 1, which is inter-
polated as having the same length as the maximum length list.
[SOURce:]ARB:CURRent:UDEFined:DWELl:POINts? (@<chanlist>)
[SOURce:]ARB:VOLTage:UDEFined:DWELl:POINts? (@<chanlist>)
[SOURce:]ARB:POWer:UDEFined:DWELl:POINts? (@<chanlist>)
[SOURce:]ARB:RESISTANCE:UDEFined:DWELl:POINts? (@<chanlist>)
Returns the number of dwell points in the user-defined Arb, not the point values.
5 SCPI Programming Reference
222 Keysight N6700C Operating and Service Guide