Parameter Typical Return
0 to maximum|MIN|MAX <max voltage>
Selects the 2 V range: SENS:VOLT:RANG 2, (@1)
l The query returns the maximum voltage that can be measured on the range that is presently set.
SENSe:VOLTage[:DC]:RANGe:AUTO 0|OFF|1|ON, (@<chanlist>)
SENSe:VOLTage[:DC]:RANGe:AUTO? (@<chanlist>)
Enables or disables seamless measurement autoranging.
Parameter Typical Return
0|OFF|1|ON, *RST OFF 0or1
Enable voltage measurement autoranging: SENS:VOLT:RANG:AUTO ON, (@1)
SENSe:WINDow[:TYPE] HANNing|RECTangular, (@<chanlist>)
SENSe:WINDow[:TYPE]? (@<chanlist>)
Selects the signal conditioning function used in scalar DC measurement calculations. Neither window
function alters the instantaneous voltage or current data returned in the measurement array.
Hanning - window is a "raised cosine" function. It is a signal conditioning function that reduces errors in
DC measurement calculations in the presence of periodic signals such as AC line ripple. This window
only works up to 4883 measurement points. The instrument will revert to a rectangular window when
the points exceed 4883.
Rectangular - window returns measurement calculations with no signal conditioning.
Parameter Typical Return
HANNing|RECTangular, *RST RECTangular RECT or HANN
Specifies a Hanning window function: SENS:WIND HANN, (@1)
Keysight N6700C Operating and Service Guide 285