l Group channel definitions are stored in non-volatile memory and are unaffected by *RST or *RCL.
Group channel settings (voltage, current, etc.) are set and saved by *RST or *RCL
SYSTem:GROup:DELete <channel>
This command does NOT apply to models N678xA SMU .
Removes the specified channel from the group. Other channels in the group are left intact.
When ungrouping a channel, you must also remove the parallel connections between the output and
sense terminals of that channel.
Parameter Typical Return
<channel> (none)
Delete channel 3 from the group: SYST:GRO:DEL 3
l For the group definitions to take effect, reboot the unit by cycling AC power or sending the
SYSTem:REBoot command.
SYSTem:GROup:DELete:ALL
This command does NOT apply to models N678xA SMU .
Deletes all groups. Returns any channels that have been grouped back to an ungrouped state.
When ungrouping a channel, you must also remove the parallel connections between the output and
sense terminals of that channel.
Parameter Typical Return
(none) (none)
Delete all groups: SYST:GRO:DEL:ALL
l For the group definitions to take effect, reboot the unit by cycling AC power or sending the
SYSTem:REBoot command.