Parameter Typical Return
LOW|HIGH1|HIGH2|HIGH3, *RST LOW LOW, HIGH1, HIGH2, or HIGH3
1,440 to 1,000,000 Hz(LOW)
33,000 to 1,000,000 (HIGH1)
20,500 to 1,000,000 (HIGH2)
8,300 to 1,000,000 (HIGH3)
<range frequency>
Sets the voltage bandwidth to HIGH3: VOLT:BWID HIGH3, (@1)
Sets the bandwidth frequency to 25 kHz: VOLT:BWID:LEV HIGH3, 25,000, (@1)
[SOURce:]VOLTage:INHibit:VON[:LEVel] <value>, (@<chanlist>)
[SOURce:]VOLTage:INHibit:VON[LEVel]? (@<chanlist>)
When enabled, as specified by VOLTage:INHibit:VON:MODE, the load module will not sink current
until the input voltage rises above the voltage-on setting. Units are in volts.
Parameter Typical Return
0 to 60 V | MIN | MAX, *RST 0.01 <voltage-on value>
Specifies a voltage-on of 4 volts: VOLT:INH:VON 4, (@1)
[SOURce:]VOLTage:INHibit:VON:MODE LATChing|LIVE|OFF
[SOURce:]VOLTage:INHibit:VON:MODE?
Specifies the behavior of the under-voltage inhibit function. When enabled (not OFF), the load module
will not sink current until the input voltage rises above the voltage-on setting specified by
VOLTage:INHibit:VON <value>.
LIVE - turns the input off whenever the voltage drops below the voltage-on setting. Turns the input
back on when the voltage reaches the voltage-on setting.
LATChing - allows the load to sink current even if the voltage subsequently drops below the voltage-
on setting.
OFF - turns the under-voltage inhibit function off.
Parameter Typical Return
LIVE|LATChing|OFF, *RST OFF LIVE, LATC, or OFF
Sets the inhibitmode to latching: VOLT:INH:VON:MODE LATC
l The under-voltage inhibit function will ignore any programmed on/off delays.
l The under-voltage inhibit function is not available when load modules are grouped.
l The under-voltage inhibit function is not available in CV operating mode.
Keysight N6700C Operating and Service Guide 301
5 SCPI Programming Reference