Getting Started Tutorial 1
Keysight U3402A User’s and Service Guide 39
Performing frequency measurements
Measuring frequency
Five ranges: 120.000 mV, 1.20000 V, 12.0000 V, 120.000 V, 750.00 V — range is
based on the voltage level of the signal, not frequency
Measurement method: Reciprocal counting technique
Signal level: 10% of range to full scale input on all ranges
Gate time: 0.1 s or 1 period of the input signal, whichever is longer
Input protection: 750 V RMS on all ranges
1 Press .
2 Connect the red and black test leads to the input terminal as shown in
Figure 1-14.
3 Probe the test points and read the display. In auto-ranging mode, the
multimeter automatically selects the appropriate range and the measurement
is displayed.
Figure 1-14 Frequency terminal connection and display
WARNING
Use the frequency counter for low voltage applications. Do not use the
frequency counter on AC power line systems.