SCPI command
syntax
This
operation manual
denotes SCPI
commands using the following
format.
(Example)
Set command:
[SOURce:
]CURent[
:LEVel]
[
:IMHediate]
[
lAMPLitude]
{<current> | MINimum | MAXimum}
SCPI commands can be
issued using
the short form. The short
form
of an SCPI
command is the section of
the
command written in
uppercase.
SCPI commands
can be sent in
the long
form or short form.
Since SCPI commands
are not case-sensitive,
CURR,
Curr, and curr
are all accepted as
the short form of
CURRent. In the long
form,
CURRENT,
Current, and current
are
all
acceptable.
A
space is
required between the
program
header section and
the data section.
Multiple data values,
when
available, are
concatenated using commas.
Commands
are
concatenated using
semicolons.
Set command:
SOURce: CURRent
MINimum; VOLTage
MINi-
mum
This is equivalent to
entering
the following Set
commands.
Set
command:
CURRent
MINimum
Set command:
VOLTage
MINimum
A colon is
required
between program
headers.
Colons and
semicolons can
be used
together to link SCPI
commands
from dif-
ferent
subsystems.
Query
command:
CURRent MINimum;
iMEASure
:CURRent?
The maximum
number of
characters
that can be
transmitted in a
single line is
256.
Special symbols and
characters
Special
symbols and
characters used
in this
manual to describe
SCPI commands
are
defined
below.
Characters and
numbers
delimited by
“I” in braces indicate
that one of
the items
is to be selected.
Do not
write braces
in the
actual program.
o indicates
program data.
Do not
write oin the
actual
program.
[]
indicates
option data.
When
option
data is not
sent with the
program,
the default
value is
sent.
Do not write
[]
in the
actual program.
Minimum
and
maximum values
In the following
example,
MIN and MAX
are used as
substitutes for
defining cer-
tain values.
Set command:
CURRent
{<current>
\
MIN
|
MAX}
For details
see
“Expanded numeric
parameters” on
page
6-7.
6-4
Remote Control
PLZ-U

Other manuals for Kikusui PLZ-U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kikusui PLZ-U Series and is the answer not in the manual?

Kikusui PLZ-U Series Specifications

General IconGeneral
BrandKikusui
ModelPLZ-U Series
CategoryControl Unit
LanguageEnglish

Related product manuals