7.1.2 1200 HLX+
26
Specication Value
Heater 64 W
Internal Resistance ≤10mΩ
Maximum Continuous Charge Current 80 A
Maximum Continuous Discharge Current 80 A
Overcharge (High Voltage) Protection Release Method Discharge below ≈14.4 ±0.2 V (3.60±0.05 V / cell)
Overcharge Protection Trigger Voltage ≈15 ±0.12 V (3.75±0.03 V / cell)
Over-discharge (Low Voltage) Protection Release Meth-
od
Charge above 11.2V ±0.4 V (2.80±0.10 V / cell)
Over-discharge Protection Trigger Voltage ≈10.2 ±0.2 V (2.50±0.05 V / cell)
Overcurrent Protection - Time delay until high charge
current triggers protection @110±5 A
≈25 Seconds
Overcurrent Protection - Time delay until high charge
current triggers protection @150±5 A
≈3 Seconds
Overcurrent Protection - Time delay until high discharge
current triggers protection @110±5 A
≈25 Seconds
Overcurrent Protection - Time delay until high discharge
current triggers protection @300±20 A
≈3.5 Seconds
Overcurrent Protection (Charging) Release Method
Discharge battery for immediate release. Wait 1 minute
for auto-release.
Overcurrent Protection (Discharging) Release Method
Charge battery for immediate release. Wait 1 minute for
auto-release.
Peak or Surge Discharge Current 350 A for less than 3 seconds
Rated Capacity 100 Ah
Recommended Charge Current ≤50 A