Chapter 6 List of Parameters
68
code
Name Descriptions Unit
Factory
setting
Modif
Setting
range
b0.02 Asynchronous motor 1
rated current
0.1 999.9A 0.1A Determined
by model
X 1 9999
b0.03 Asynchronous motor 1
rated frequency
1.00 1000.00Hz 0.01Hz Determined
by model
X 100
30000
b0.04 Asynchronous motor 1
polarities number
2 24 1 4 X 2 24
b0.05 Asynchronous motor 1
rated speed
0 60000RPM 1RPM 1440RPM X 0 60000
b0.06 Asynchronous motor 1
stator resistance %R1
0.00% 50.00% 0.01% Determined
by model
X 0 5000
b0.07 Asynchronous motor 1
leakage inductance %X
0.00% 50.00% 0.01% Determined
by model
X 0 5000
b0.08 Asynchronous motor 1
rotor resistance %R2
0.00% 50.00% 0.01% Determined
by model
X 0 5000
b0.09 Asynchronous motor 1
mutual inductance %Xm
0.0% 2000.0% 0.1% Determined
by model
X 0 20000
b0.10 Asynchronous motor 1
no-load current I0
0.1 999.9A 0.1A Determined
by model
X 1 9999
b0.11 Asynchronous motor 1
parameter auto-tuning
0: disable
1: Stationary auto-tuning
(Start auto-tuning to a standstill motor)
2: Rotating auto-tuning
3: Reserved
(calculated by nameplate setting)
1 0 X 0 3
b0.12 Asynchronous motor 1
overload protection
coefficient
20.0% 110.0% 0.1% 100.0% X 200 1100
b0.13 Asynchronous motor 1
overload protection time
0.0 6000.0
0.0:
Calculate the overload according to
the internal overload curve
0.1s 0.0s X 0 60000
b0.14 Asynchronous motor 1
oscillation inhibition
coefficient
0 255 1 10 O 0 255
b0.15 Synchronous motor 1
rated power
0.4 999.9KW 0.1KW Determined
by model
X 4 9999
b0.16 Synchronous motor 1
rated voltage
0 inverter rated voltage (F82.04)
2 series: 220V
4 series: 380V
1V Determined
by model
X 0 999
b0.17 Synchronous motor 1
rated current
0.1 999.9A 0.1A Determined
by model
X 1 9999
b0.18 Synchronous motor 1
rated frequency
1.00 1000.00Hz
(Note: Pole number and rated
frequency can be calculated from each
other by only setting one of them.)
0.01Hz Determined
by model
X 100
100000