Chapter 6 List of Parameters
80
code
Name Descriptions Unit
Factory
setting
Modif
Setting
range
C2.24 Step 12 operating time 0.0 6500.0 0.1 20.0 O 0 65000
C2.25 Step 13 setting Same as C2.01 1 000 O 0 323H
C2.26 Step 13 operating time 0.0 6500.0 0.1 20.0 O 0 65000
C2.27 Step 14 setting Same as C2.01 1 000 O 0 323H
C2.28 Step 14 operating time 0.0 6500.0 0.1 20.0 O 0 65000
C2.29 Step 15 setting Same as C2.01 1 000 O 0 323H
C2.30 Step 15 operating time 0.0 6500.0 0.1 20.0 O 0 65000
Group C3.textile swing function
C3.00 Tex tile function selection 0: Not choose textile function
1: Select textile function
1 0 X 0 1
C3.01 Swing frequency
operation
LED unit position: starting mode
0: automatic
1: terminal manual
LED ten position: swing control
0: Relative center frequency
1: Relative maximum frequency
LED Hundreds: Swing Frequency State
Memory
0: shutdown memory
1: stop without memory
LED Thousands: Swing Frequency
Status Power Down Storage
0: storage
1: not stored
1 0000 X 0
11111H
C3.02 Swing frequency preset
frequency
0.00Hz upper limit frequency 0.01Hz 0.00Hz O 0 30000
C3.03 Swing frequency preset
frequency waiting time
0.0 3600.0s 0.1s 0.0s O 0 36000
C3.04 Swing frequency
amplitude
0.0% 50.0% 0.1% 0.0% O 0 500
C3.05 Mutation frequency 0.0% 50.0% 0.1% 0.0% O 0 500
C3.06 Wobble cycle 0.1 999.9s 0.1s 10.0s O 1 9999
C3.07 Triangle wave rise time 0.0% 100.0%
(refer to the swing frequency period)
0.1% 50.0% O 0 1000
Group d0.Status display
d0.00
Main reference frequency
-300.00 300.00Hz 0.01Hz 0.00 * 0 60000
d0.01 Auxiliary reference
frequency
-300.00 300.00Hz 0.01Hz 0.00 * 0 60000
d0.02 Preset frequency -300.00 300.00Hz 0.01Hz 0.00 * 0 60000
d0.03
Frequency after Acc/Dec
-300.00 300.00Hz 0.01Hz 0.00 * 0 60000
d0.04 Output frequency -300.00 300.00Hz 0.01Hz 0.00 * 0 60000
d0.05 Output voltage 0 60000V 1V 0 * 0 60000
d0.06 Output current 0.0 3Ie 0.1A 0.0 * 0 65535
d0.07 Torque current -300.0 +300.0% 0.1% 0.0% * 0 6000
d0.08 Magnetic flux current 0 +100.0% 0.1% 0.0% * 0 1000