RO Compact Series Technical Manual
70
RO-Compact without bypass
By-pass conversion kit - 170018:
1. Shut o the water.
2. Remove cable/wire from elbow.
3. Remove top of solenoid valve, 4 screws.
4. Remove bottom of solenoid valve, together
with check valve from pipe system.
5. Remove JG connector 18mm and tube.
6. Install end cap on pipe system.
7. Install pressure switch, PVC fittings 15 x 1/8”
and reducer 18 x 15.
8. Connect parallel pressure-switch and flow-
switch with green and yellow wires.
Part Number Description
170153-U RO-Compact 3 without bypass
170152-U RO-Compact 2 without bypass
Part Number Description Pieces
170083 Red Shrouded Receptacle 2
170277 JG Reducer 18 x 15 1
170309 Pressure Switch 1 - 10 Bar - 1/8" 1
660002 Cap Nut - 1/2" 1
700061 PVC L40mm - 1/8" 1
170312 Hood for Pressure Switch 1
170087 Wire (50cm) 0,50
Pressure switch preset at 1,6 bar