Model #
TQ 172 TQ 173 TQ 172n TQ 173n TQ 174 TQ 176
Inlet Filter
Membrane Performance
Membrane Type
Membrane Dimensions
Number of Membranes 232346
Square Footage of each Membrane
Array Configuration
Drain Control
Permeate Flush, per membrane
System Shut-Off Control
System Controller
Power
Inlet Connection
Permeate Connection
Drain Connection
EverClean Rinse Connection
Pressure
Temperature
pH
Chlorine
Hardness (Max.) 4 gpg 4 gpg 20 gpg 20 gpg 4 gpg 4 gpg
Silica (Max.)
Iron (Max.)
Total Dissolved Solids (Max.)
Inlet Flow Rate 0.2 gpm 0.3 gpm 0.2 gpm 0.42 gpm .42 gpm .62 gpm
Permeate Flow Rate 0.1 gpm 0.15 gpm 0.1 gpm 0.21 gpm .21 gpm .31 gpm
Reject Flow Rate 0.1 gpm 0.1 gpm 0.1 gpm 0.21 gpm .21 gpm .31 gpm
Daily Production* 150 gpd 225 gpd 200 gpd 300 gpd 300 gpd 450 gpd
Operating Pressure Range
Normal Operating Pressure
Rejection Rate - NaCl > 95% > 95% > 50% >50 % > 95% > 95%
Rejection Rate - Ca
2
SO
4
> 99% > 99% > 85% >85 % > 99% > 99%
Recovery Ratio Atmospheric 50% 50% 50% 50% 50% 50%
EverClean Rinse Volume
10 oz. 15 oz. 10 oz. 15 oz. 20 oz. 30 oz.
Width
Depth
Height
Weight 10 lbs. 13 lbs. 10 lbs. 13 lbs. 50 lbs. 58 lbs.
Part #
10162 10163 10166 10167 11585 11560
* Based on 77 degree F water, 500 TDS feed, Permeate to Atmospheric Tank, 70psi operating pressure
70 - 90 psi
8.5"
18.75
20.5
5 oz reservoir
Capillary Tube
Parallel
1.6 Ft
2
18"
6"
18"
40 - 100 psi
70 psi
< 0.1 mg/l as Fe
< 2,500 mg/l as NaCl
20 - 80 psi
40 - 100 psi
40 - 95
o
F
4-11 SU
< 0.05 mg/l as Cl
2
< 10 mg/l as SiO
2
20 - 80 psi
Internal/Automatic
3/8" Tubing
3/8" Tubing
3/8" Tubing
None
Sediment Cartridge
Low Energy RO or Nanoflitration
1.75" x 11"
Thin Film Composite
120/60 or 230/50
None
Low Energy
Hydraulic
Internal Pressure
Operating Specifications
General operating parameters for the TQ product line have been listed in the table below. These
specifications have been provided to express the required conditions for the operation of this system. If there
are other parameters that you may be concerned about, please contact your local Kinetico Dealer for further
operating or performance data.
Exceeding the conditions in the table below may inhibit
performance or could cause the system to be permanently
damaged.
To assure that these factors are being met, a yearly water analysis is recommended to keep track of your
influent water quality. This can be a beneficial tool in recognizing changes in your inlet water supply. If the
inlet supply does change, please contact your area Kinetico Dealer. Modifications to the system or additional
equipment may be required to maintain peak operation efficiency of your system.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kinetico TQ 172 and is the answer not in the manual?

Kinetico TQ 172 Specifications

General IconGeneral
BrandKinetico
ModelTQ 172
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals