3) Use a damp cloth to wipe out all dust in the air cleaner.
4) Thorough cleaning of the fitter element with compressed air is recommended.
5) Clean the element from inside to outside using the pressurised air pipe.
IMPORTANT - Too much air pressure can break the filter paper and destroy the element. (Max. Air
Pressure 3.0 kg/cm2)
6) Replace the main element after two cleaning intervals.
7) Rapping, Tapping or Pounding dust out of them is dangerous. Severe damage to the filter will result!
8) Carefully check new or properly cleaned element for damage before installing. Conduct a light test by
passing the light through element as shown in Figure. If there is any crack in the element, the light
will pass through it. In that case replace the element.
9) The inner element (Safety element) is not to be removed, when the main element is removed for
cleaning/ replacement. It should be replaced by a new safety element after every three changes of
the main element.
10) Replace the cleaned or new element in the air cleaner body and reinstall the end cover, making sure
it seals 360° around the air cleaner body. Reset the restriction indicator by pressing the button at the
top.