4
ENGLISH
WARNINGS
To ensure safe operation and service of the meter, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
Before each use, verify meter operation by measuring a known voltage
or current.
Never use the meter on a circuit with voltages that exceed the category
based rating of this meter.
Do not use the meter during electrical storms or in wet weather.
Do not use the meter or test leads if they appear to be damaged.
Use only with CAT III or CAT IV rated test leads.
Ensure meter leads are fully seated, and keep fingers away from the
metal probe contacts when making measurements.
Use caution when working with voltages above 25V AC RMS or
60V DC. Such voltages pose a shock hazard.
To avoid false readings that can lead to electrical shock, replace batteries
when a low battery indicator appears.
Do not attempt to measure resistance or continuity on a live circuit.
Do not hold meter above hand & finger guard during use.
ELECTRICAL SPECIFICATIONS
Frequency
9.999Hz 0.001Hz
±(1.0% + 5 digits)
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
500.0kHz 100Hz
Sensitivity: >8V RMS, Maximum Input: 600V DC or 600V AC RMS
Duty Cycle
0.1% – 99.9% 0.10%
±(1.2% + 2 digits)
Pulse width: 0.1ms – 100ms
Frequency width: 5Hz to 10kHz
Sensitivity: >8V RMS
Maximum Input: 600V AC RMS or 600V DC
OTHER MEASUREMENT APPLICATIONS
Diode Test: Max. 1.5mA, open circuit voltage ~ 3.0V DC
Continuity Check: Audible signal <50Ω, test current <0.35mA
Sampling Frequency: 3 samples per second
Low Impedence (Low Z): Input impedence: >3kΩ
Max input: 600V RMS
Auto Power off: After ~30 minutes of inactivity
Overload:
"OL" indicated on display, overload protection
1000V RMS in Voltage setting, 600V RMS in all other settings
Polarity: "-" on display indicates negative polarity
Non-Contact Voltage Detection:
>90V AC
Display: 3-5/6 digit, 6000 Count LCD
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools CL900 and is the answer not in the manual?

Klein Tools CL900 Specifications

General IconGeneral
BrandKlein Tools
ModelCL900
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals