3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy (50/60 Hz)
AC Voltage
(V AC)
600.0mV 0.1mV ±(1.0% + 8 digits)*
6.000V 1mV ±(1.0% + 5 digits)
60.00V 10mV
±(1.2% + 5 digits)
600.0V 0.1V
1000V 1V ±(1.5% + 5 digits)
DC Voltage
(V DC)
600.0mV 0.1mV ±(0.9% + 8 digits)
6.000V 1mV
±(1.0% + 3 digits)60.00V 10mV
600.0V 0.1V
1000V 1V ±(1.2% + 3 digits)
Input Impedance:
10MΩ
Frequency Range:
50 to 400Hz
Maximum Input: 1000V AC RMS or 1000V DC
*Accuracy specified from 5% to 100% of the measuring range
AC Current
(A) TRMS
600.0A 0.1A ±(2.0% + 5 digits)
2000A 1A ±(2.5% + 8 digits)
DC Current (A)
600.0A 0.1A ±(2.0% + 5 digits)
2000A 1A ±(2.5% + 8 digits)
AC Frequency Range: 50 to 60Hz , >500mA
DC:
>200mA (low current requires use of DC ZERO function)
AC Current (A)
Inrush
600A 0.1A ±(2.5% + 5 digits)**
2000A 1A ±(3.0% + 8 digits)**
AC Frequency Range: 50 to 60Hz
when auto-ranging >3A detectable
(>2A if held in 600A range)
**Accuracy specified assumes AC sine wave
Resistance
600.0Ω 0.1Ω
±(1.5% + 5 digits)
6.000KΩ 1Ω
60.00kΩ 10Ω
600.0kΩ 100Ω
6.000MΩ 1kΩ
60.00MΩ 10kΩ ±(2.0% + 10 digits)
Maximum Input: 600V AC RMS or 600V DC
Capacitance
60.00nF 10pF ±(5.0% + 35 digits)
600.0nF 0.1nF
±(3.0% + 5 digits)
6.000µF 1nF
60.00µF 10nF
600.0µF 0.1µF
6000µF 1µF ±(5.0% + 5 digits)
Maximum Input: 600V AC RMS or 600V DC
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com