C-48 APPENDIX C General Setup, Configuration and Troubleshooting
Series 3000 Sonar System Operations and Maintenance Manual 11210066, Rev. 11
C.10 TPU Operating System Notes (vxWorks)
CPU version 14102073 recognized by unpopulated area near front
of board can only be used with vxWorks version 5.5.0291 or
earlier. This board may be reflashed with an updated boot file to
make it compatible with the newer vxWorks files.
CPU version 14103184 can only be used with vxWorks version
5.11.1841 or higher.
vxWorks version 5.27.0788 should use a new startup.ini file. The
following line should be added:
set TOWFISHECHO 0