5-16 CHAPTER 5 Splashproof-II TPU
Series 3000 Sonar System Operations and Maintenance Manual 11210066, Rev. 11
5.
Turn on the SP-II TPU by switching the A/C-D/C switch to A/C for AC operation
or to D/C for DC operation.
The PWR, T/F PWR and LOCK LOSS indicators should illuminate, then after
approximately 45 seconds, the LOCK LOSS indicator should turn off and the
T/F TRIG indicator should begin flashing at the ping rate of the sonar.
6. On the computer, start SonarPro and observe that the towfish is transmitting by
viewing the output pulse in the Sonar Viewer window. Also check that navigation
data are being displayed in the Information window.
5.8 Specifications
Size: 50.24 cm (19.78 in.) wide
17.1 cm (6.72 in.) high
32.7 cm (12.89 in.) deep
Weight: 6.8 kg (15.0 lb)
Operating temperature: 0–40° C
Ingress protection: Designed to IP-66
Power consumption: 250 VA (nominal)
Input voltage: 88–264 VAC, 47–63 Hz, 140 watts max
or
11–12 VDC, 135 watts max
NOTE Should the DC power cord be connected with the polarities
reversed, the D/C POLARITY indicator will illuminate when the A/C-D/C
switch is switched to D/C. Should this situation occur, reverse the
connection.
CAUTION Serious damage to the towfish electronics may occur if the
towfish is operated on deck for periods longer than fifteen minutes.
Between periods of operation, let the sonar cool for fifteen minutes. In high
temperature climates, protect the towfish from direct exposure to the sun prior to and
during operation.
NOTE Specifications are typical and subject to change without notice.