KMS MD35 manual
Version 4.16 45
One shot with reset
The aux output (aux pin in the graph) will be activated when the criteria (aux result) that have
been set for mode 0 or mode 1, are met/fullfilled. The aux output will be deactived when either
the timer expires or when the aux result is expired.
Delay with reset
The aux output (aux pin in the graph) will be activated when the criteria (aux result) that have
been set for mode 0 or mode 1, are met/fullfilled and the timer has expired/finished. As soon as
the aux result drops below the criteria, the timer is reset and the aux output expires.
Delay without reset
The aux output (aux pin in the graph) will be activated when the criteria (aux result) that have
been set for mode 0 or mode 1, are met/fullfilled and the timer has expired/finished. As soon as
the aux result drops below the criteria, the timer isn‟t reset untill the aux output also expires.