4-4 A-61602 June 2013
Cleaning the calibration
area
1. Press the release button to open the scanner cover.
2. Remove dust and debris from this area by using a Staticide wipe or
a small brush. Be careful not to scratch the glass (may cause
image quality problems) or bend the white tabs on the front
calibration guide (bending the tabs may cause paper feeding
problems) when cleaning the calibration area.
IMPORTANT: Staticide wipes contain isopropanol which can cause eye
irritation and dry skin. Wash your hands with soap and
water after performing maintenance procedures. Refer to
the MSDS for more information.
3. Wipe the front and rear calibration guides again with an almost-dry
Staticide wipe to remove any streaks.
IMPORTANT: When cleaning the front calibration area, be careful not to
bend the white tabs; bending the tabs may cause paper
feeding problems.
4. When finished, close the scanner cover.
Replacement
procedures
Replacing the pre-
separation pad
Degradation of feeder performance, multiple feeds, stoppages, etc.
indicate a need to change the pre-separation pad. Certain paper types
such as carbonless paper or newsprint, or failure to clean regularly,
and/or use of non-recommended cleaning solvents can shorten the pre-
separation pad life.
NOTE: Disconnect the electrical power before beginning replacement
procedures.
For additional pre-separation pads, see the section entitled, “Supplies
and consumables” later in this chapter.