6HFWLRQ
(OHFWULFDO6\VWHPDQG&RPSRQHQWV
)LJXUH$PS6WDWRUDQG5HFWL¿HU5HJXODWRU
)LJXUH$PS6WDWRUDQG5HFWL¿HU5HJXODWRU
6WDWRU
The stator is mounted on the crankcase behind
the ywheel. Follow the procedures in Section 8,
Disassembly and Section 10, Reassembly if stator
replacement is necessary.
5HFWL¿HU5HJXODWRU
The rectier-regulator is mounted to the underside of
the backing plate on the oil lter side. See Figure 7-21.
To replace it, remove the two mounting screws and
disconnect the plug.
NOTE: When installing the rectier-regulator, take
note of the terminal markings and install the
plug accordingly.
)LJXUH5HFWL¿HU5HJXODWRU/RFDWLRQ
Testing of the rectier-regulator may be performed
as follows, using the appropriate Rectier-Regulator
Tester.
7R7HVW±
NOTE: Disconnect all electrical connections aached
to the rectier-regulator. Testing may be
performed with the rectier-regulator
mounted or loose. The gures show the part
removed from the engine for clarity. Repeat
the applicable test procedure two or three
times to determine the condition of the part.
$PS5HFWL¿HU5HJXODWRUV
1. Connect the tester ground lead (with spring
clamp) to the body of the rectier-regulator being
tested.
2. Connect the tester red lead to the B+ terminal of
the rectier-regulator and the two black tester
leads to the two AC terminals. See Figure 7-22.
)LJXUH