8.6
Section 8
Disassembly
)LJXUH5HPRYLQJ,QQHU%DIÀHV
Remove Ignition Modules
1. Rotate the ywheel so the magnet is away from
the modules.
2. Disconnect the lead(s) from each ignition module.
Fixed Timing Models and DSAI Models have one
lead per module and DSAM or SMART-SPARK™
(variable timing) ignition modules have two leads
per module. See Figure 8-21.
3. Remove the mounting screws and ignition
modules. Note the position of the ignition
modules.
Figure 8-21. Removing Ignition Modules.
5HPRYH,QWDNH0DQLIROGDQG5HFWL¿HU
Regulator
1. Remove the four hex ange screws securing
the intake manifold to the cylinder heads. Note
which screws hold the wiring clamp(s).
2. Remove the intake manifold and O-Rings. Leave
the wiring harness aached to the manifold. See
Figure 8-22.
5HPRYH,QQHU%DIÀHV
1. Remove the mounting screws securing the two
inner baes to the crankcase. Note the position
of any liing bracket(s). Remove the inner baes.
See Figure 8-20.
,QQHU%DIÀHV
Mounting Screws
,QQHU%DIÀH
(# 2) Side
Lifting
Strap
Standard (Fixed) Timing Ignition
Module (Single Lead) shown
DSAM or SMART-SPARK™
Ignition Module (Two-Leads)
Figure 8-22. Intake Manifold Mounting Locations.
Intake Manifold Mounting
Locations