6HFWLRQ
(OHFWULFDO6\VWHPDQG&RPSRQHQWV
(OHFWULF6WDUWLQJ0RWRUV
These engines may use either an inertia drive or
solenoid shi style electric starter. The inertia
drive starter is covered rst and the solenoid shi
following.
6WDUWLQJ0RWRU3UHFDXWLRQV
NOTE: Do not crank the engine continuously for
more than 10 seconds at a time. If the engine
does not start, allow a 60 second cool-down
period between starting aempts. Failure
to follow these guidelines can burn out the
starter motor.
3UREOHP 7HVW &RQFOXVLRQ
1. Trace B+ lead from rectier-regulator to
key switch, or other accessible connection.
Disconnect it from switch or connection.
Connect an ammeter from loose end of B+
lead to positive terminal of baery. Connect
DC voltmeter from loose end of B+ lead to
negative terminal of baery. With engine
running at 3600 RPM, read voltage on
voltmeter.
If voltage is 13.8 volts or more, place a
minimum load of 5 amps* on baery to
reduce voltage. Observe ammeter.
*NOTE: Turn on lights, if 60 was or more.
Or place a 2.5 ohm, 100 wa resistor
across baery terminals.
1. If voltage is 13.8-14.7 and charge rate increases
when load is applied, the charging system is
OK and baery was fully charged.
If voltage is less than 13.8 or charge rate does
not increase when load is applied, test stator
(Tests 2 and 3).
2. Remove connector from rectier-regulator.
With engine running at 3600 RPM, measure
AC voltage across stator leads using an AC
voltmeter.
2. If voltage is 28 volts or more, stator is OK.
Rectier-regulator is faulty. Replace the
rectier-regulator.
If voltage is less than 28 volts, stator is probably
faulty and should be replaced. Test stator
further using an ohmmeter (Test 3).
1R&KDUJH
WR%DWWHU\
3a. With engine stopped, measure the resistance
across stator leads using an ohmmeter.
3a. If resistance is 0.064/0.2 ohms, the stator is OK.
If the resistance is innity ohms, stator is open.
Replace stator.
3b. With the engine stopped, measure the
resistance from each stator lead to ground
using an ohmmeter.
3b. If the resistance is innity ohms (no continuity),
the stator is OK (not shorted to ground).
If resistance (or continuity) is measured, the
stator leads are shorted to ground. Replace
stator.
1. If the voltage is 14.7 volts or less the charging
system is OK. The baery is unable to hold a
charge. Service baery or replace as necessary.
If voltage is more than 14.7 volts, the rectier-
regulator is faulty. Replace rectier-regulator.
1. Perform same test as step 1 above.
%DWWHU\
&RQWLQXRXVO\
&KDUJHVDW
+LJK5DWH
NOTE: If the engine develops sucient speed to
disengage the starter but does not keep
running (a false start), the engine rotation
must be allowed to come to a complete stop
before aempting to restart the engine. If
the starter is engaged while the ywheel is
rotating, the starter pinion and ywheel ring
gear may clash, resulting in damage to the
starter.