4 — PROGRAMMABLE PARAMETERS
pg. 97
Return to TOC Curtis AC F2-A, F4-A, F6-A Motor Controllers – FOS 4.5 – April 2022
APPLICATION SETUP/VEHICLE — PERFORMANCE METRICS MENU, cont’d
PARAMETER ALLOWABLE RANGE DEFAULT DESCRIPTION
Time to Dist 3
Time_to_Capture_Distance_3
0x37D2 0x00
0.00 – 128.00 s
0 – 32000
Read Only Time taken for the vehicle to travel from zero rpm to the
programmed Capture Distance 3 during its most recent such trip.
For accurate distance measurements, the Speed to RPM
parameter must be set correctly.
Braking Distance Captured
Braking_Distance_Captured
0x37C0 0x00
0.0 – 1000000.0
0 – 40000000
Read Only
Feet or
Meters
Distance traveled by the vehicle starting with vehicle braking
(initiated by throttle reversal, VCL_Brake, or interlock braking) and
ending when Motor_RPM = 0. Units are meters or feet, depending
on the setting of the Metric Units parameter.
For accurate distance measurements, the Speed to RPM
parameter must be set correctly.
Distance Since Stop
Distance_Since_Stop
0x37C8 0x00
0.0 – 1000000.0
0 – 40000000
Read Only
Feet or
Meters
Distance traveled by the vehicle starting from a stop. In effect,
it uses the vehicle as a tape measure. (In other words, if you
travel 300 feet forward and then 300 feet in reverse, the distance
would be 600.) The distance is continuously updated and will
stop (and restart) when Motor_RPM = 0. For accurate distance
measurements, the Speed to RPM parameter must be set
correctly. Units are meters or feet, depending on the setting of the
Metric Units parameter.
Usage examples:
Set the Speed to RPM parameter by using this variable to cover
a known distance (e.g., 50 feet). Adjust the Speed to RPM
parameter until this value matches the known distance.
Distance Fine
Distance_Fine_Long
0x37C7 0x00
0.0 – 1000000.0
0 – 40000000
Read Only
Inches or
Decimeters
Position measurement. Net distance in both the forward and
reverse directions. (In other words, if you travel 20 inches forward
and then 20 inches in reverse, the distance would be zero.) The
distance is continuously updated and will roll over when the
variable goes over the limits. Resets to zero on key cycle. Units
are decimeters or inches, depending on the setting of the Metric
Units parameter.
For accurate distance measurements, the Speed to RPM
parameter must be set correctly.
Reset Distance Fine
Reset_Distance_Fine
0x37CA 0x00
0 – 1
0 – 1
0 Resets the Distance Fine value.