Exhaust aftertreatment system
Fig. 283: Nuts tightening sequence
u Tighten the nuts to 18.5
±1.5
Nm (14
±1
ft-lb).
Information
Observe the nuts tightening sequence.
Fig. 284: Removing shipping caps
u Remove the shipping caps 1, 2, 4 from the injector.
u Connect the diesel exhaust fluid inlet line.
u Connect the diesel exhaust fluid return line.
u Connect the electrical connector.
u Run the system for 30 min to confirm leak-free operation.