Maintenance Operation and Maintenance Manual
Cooling system
5.8.3 Inspecting low temperature circuit (charge air cooler) — SL002
Fig. 74: Low Temperature circuit drain holes
At drain holes:
u Check for leakage.
In case of water leakage:
u The leakage of condensation water is not an issue. Let the condensation water flows out.
In case of air leakage:
u Air leakage is normal.
In case of water mixed with antifreeze leakage:
u Inspect charge air cooler for leaks. If necessary, have the leaks repaired by the competent
personnel.