Maintenance Operation and Maintenance Manual
Cooling system
5.8.5 Coolant drain points — SL116
DANGER
Hazards by ejection of hot operating fluids or filler cap!
Hot fluid spray from a pressurized cooling system will cause death or serious injuries by burns.
Filler cap ejected by operating fluid under pressure will cause death or serious injuries by impact.
u Only perform maintenance and inspection work on the cooling system when the engine has
cooled down to ambient temperature.
u Wear proper personal protective equipment.
Ensure that:
q Preparatory maintenance activities are fullfilled. (For more information see: 5.5 Preparatory
maintenance activities, page 90)
q A container with the required capacity is ready.
q A suitable drainage container is available.
q The required quantity of approved coolant is provided. (For more information see: 5.11 Lubri-
cants and operating fluids, page 120)
Fig. 76: Coolant drain points
u Drain coolant system at the deepest point. Refer to the generator set manual.