Error code
SPN FMI Designation
516191 17 Injector supply boost converter - Undervoltage warning
105 5 Intake air temperature sensor - Open circuit
105 3 Intake air temperature sensor - Short circuit to battery
105 4 Intake air temperature sensor - Short circuit to ground
105 31 Intake air temperature sensor - Supply voltage out of range
102 0 Intake manifold - Critical overpressure
1636 0 Intake manifold - Critical overtemperature
102 1 Intake manifold - Critical underpressure
102 15 Intake manifold - Overpressure warning
1636 15 Intake manifold - Overtemperature warning
102 17 Intake manifold - Underpressure warning
102 3 Intake manifold pressure sensor - Short circuit to battery
102 4 Intake manifold pressure sensor - Short circuit to ground or open
circuit
102 31 Intake manifold pressure sensor - Supply voltage out of range
1636 5 Intake manifold temperature sensor - Open circuit
1636 3 Intake manifold temperature sensor - Short circuit to battery
1636 4 Intake manifold temperature sensor - Short circuit to ground
1636 31 Intake manifold temperature sensor - Supply voltage out of range
6209 5 Intercooler coolant temperature sensor - Open circuit
6209 3 Intercooler coolant temperature sensor - Short circuit to battery
6209 4 Intercooler coolant temperature sensor - Short circuit to ground
6209 31 Intercooler coolant temperature sensor - Supply voltage out of
range
516197 2 Master Slave Injection - Communication error
516223 11 Monitoring System - Ecu internal safety error
516226 11 Monitoring System - Injector safety error
100 3 Oil pressure sensor - Short circuit to battery
100 4 Oil pressure sensor - Short circuit to ground or open circuit
100 31 Oil pressure sensor - Supply voltage out of range
175 5 Oil temperature sensor - Open circuit
175 3 Oil temperature sensor - Short circuit to battery
175 4 Oil temperature sensor - Short circuit to ground
175 4 Oil temperature sensor - Short circuit to ground or open circuit
175 31 Oil temperature sensor - Supply voltage out of range
4811 0 Piston cooling pressure 1 - Critical overpressure
4811 1 Piston cooling pressure 1 - Critical underpressure
4811 15 Piston cooling pressure 1 - Overpressure warning
KD83V16 33521030601_0_1 EN_US
2018-07
© 2018 by Kohler Co. All rights reserved.
153

Table of Contents

Other manuals for Kohler KD83V16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KD83V16 and is the answer not in the manual?

Kohler KD83V16 Specifications

General IconGeneral
BrandKohler
ModelKD83V16
CategoryEngine
LanguageEnglish

Related product manuals