5
INFORMATION ABOUT MAINTENANCE
32
5.4 Air filter check
•
Before proceeding with operation, read Par. 3.2.2.
NOTE
: Components not necessarily supplied by
KOHLER
.
1.
Release the two clasps F of the cover A.
2.
Remove the cartridge B.
3.
Clean the inside components A and D with a damp cloth.
4.
Do not use compressed air , repeatedly tap the front side E on
a flat surface.
5.
Reinstall:
cartridge B.
the cover A checking the right tightness of clasps F.
Fig 5.3
5.5 Check of the radiator heat - exchanger surface
•
For safety precautions see Chap. 3.
NOTE:
Component not necessarily supplied by
KOHLER
.
Important
•
Before proceeding with operation, read Par. 3.2.2.
•
Wear safety goggles when using compressed air.
•
The radiator heat-exchange surface must be cleaned on both.
1.
Check the radiator heat-exchange surface D.
2.
Clean the surface with a brush soaked in special detergent if it
is clogged.
Fig 5.4