INFORMATION ABOUT FAILURES
7
43
EN
Internal Communication: For internal & partner use only.
7 INFORMATION ABOUT FAILURES
7.1 Useful information about failures
• This chapter contains information about the problems that may appear during engine operation with its
causes and trouble shooting Tab. 7.2.
• In some cases, you shall turn off the engine immediately to avoid further damage Tab. 7.1.
Tab 7.1
THE ENGINE MUST BE IMMEDIATELY TURNED OFF WHEN
Warning RED light turn on
The oil pressure indicator light turns on while running
The engine rpms suddenly increase and decrease
A sudden and/or unusual noise is heard
Colour the exhaust fumes suddenly darkens
Tab 7.2
Warning YELLOW light
turn on
Engine ECU has detect a
malfunctions
Contact KOHLER authorised workshops
--
The engine does not
start
Sulphated battery terminals
corroded
Clean the battery terminals
--
Recharge the battery or replace it
Contact KOHLER authorised workshops
Replace with a new filter
Air suction in fuel system
Contact KOHLER authorised workshops
Clogged air filter
Replace with a new filter
Contact KOHLER authorised workshops
Intake or exhaust system
clogged
Replace with a new fuse; if the problem persists,
Contact KOHLER authorised workshops
--
Intake or exhaust system
clogged
Contact KOHLER authorised workshops
--
Engine starts but stops
Inefficient electrical
connections
Clean the electrical contacts; if the problem persists,
Contact KOHLER authorised workshops
--
Sulphated battery terminals
Clean the battery terminals
Replace with a new filter and clean the tank
Contact KOHLER authorised workshops
Engine doesn't rev up
Safety protocol in starting
Throttle to MAX in starting
Release the throttle and wait some seconds
speed
Clogged fuel pipes
Contact KOHLER authorised workshops
--
Numero dei giri al
minimo basso
Contact KOHLER authorised workshops
Clean the tank and refuel with quality fuel