EasyManua.ls Logo

Kollmorgen S70601-SE - User Manual

Kollmorgen S70601-SE
139 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
(217) 352-9330 | sales@artisantg.com | artisantg.com
-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your
definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
Critical
and
expedited
services
Leasing
/
Rentals/
Demos
In
stock/
Ready-to-ship
!TAR-certified
secure
asset
solutions
Expert
team
I
Trust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Danaher Motion / Kollmorgen S70601-SE at our website: Click HERE

Table of Contents

Questions and Answers

  • Z
    Zachary MillerSep 18, 2025
    Why does my Kollmorgen Servo Drives axis drifts at setpoint = 0V?
    • J
      Johnny WilliamsonSep 18, 2025
      If your Kollmorgen Servo Drives axis drifts at a setpoint of 0V, it could be because the offset is not correctly adjusted for analog setpoint provision; adjust the offset (analog I/O). Another potential cause is that AGND is not joined to the controller-GND of the controls; join AGND and controller-GND.
  • S
    sharon00Aug 25, 2025
    How to solve communication fault HMI message on Kollmorgen Servo Drives?
    • D
      Dalton HicksAug 25, 2025
      A communication fault HMI message on Kollmorgen Servo Drives can be caused by using the wrong cable, plugging the cable into the wrong position on the servo amplifier or PC, or selecting the wrong PC interface. Use a null-modem cable, plug the cable into the correct sockets on both the servo amplifier and PC, and select the correct interface to resolve this issue.
  • S
    Stephen GordonAug 25, 2025
    What to do if my Kollmorgen Amplifier drive reports a following error?
    • G
      Gabrielle Matthews DDSAug 26, 2025
      If your Kollmorgen Amplifier drive reports a following error, it could be due to the current settings being too low or the setpoint ramp being too long. Try increasing the current settings, but stay within the motor limits, or shorten the setpoint ramp.
  • C
    Christine Gonzalez DDSAug 27, 2025
    How to fix Kollmorgen S70601-SE Amplifier communication fault?
    • K
      Kevin SmithAug 27, 2025
      To resolve a communication fault HMI message on your Kollmorgen Amplifier, ensure you are using the correct null-modem cable and that the cable is plugged into the correct sockets on both the servo amplifier and the PC. Also, verify that the correct PC interface is selected.
  • S
    Sharon NicholsonSep 18, 2025
    What to do if my Kollmorgen Amplifier motor does not rotate?
    • B
      Brian DurhamSep 18, 2025
      If the motor does not rotate, several factors could be at play. First, ensure the servo amplifier is enabled by applying the ENABLE signal and setting the software enable. Check the setpoint cable for any breaks and correct the motor phase sequence if the phases are swapped. Also, verify the brake control to ensure the brake is released and inspect the mechanism for any mechanical blockages. Confirm that the motor pole number is set correctly and that the feedback is properly configured.
  • K
    kowensSep 23, 2025
    What to do if Kollmorgen Amplifier axis drifts at setpoint = 0V?
    • G
      Gregory KleinSep 23, 2025
      If the axis drifts when the setpoint is at 0V, it might be due to an incorrectly adjusted offset for the analog setpoint provision; in this case, adjust the offset (analog I/O). Another potential cause is AGND not being joined to the controller-GND of the controls; connect AGND and controller-GND.
  • J
    josephbrownSep 9, 2025
    Why does my Kollmorgen Amplifier drive feel too soft?
    • P
      phillipsderrickSep 9, 2025
      If the Kollmorgen Amplifier drive is too soft, the gain might be too low, or other settings might be incorrect. Try increasing the gain and using the motor's default value. Reduce the ARLPF / ARHPF and reduce ARLP2.
  • H
    Heather HernandezSep 10, 2025
    Why does my Kollmorgen S70601-SE drive run roughly?
    • E
      Elizabeth KnightSep 10, 2025
      If the Kollmorgen Amplifier drive runs roughly, it could be due to incorrect gain settings. Try reducing the gain and using the motor's default value. Increase the ARLPF / ARHPF and increase ARLP2.
  • B
    bwalkerSep 3, 2025
    Why is my Kollmorgen Servo Drives too soft?
    • C
      Christine JohnsonSep 3, 2025
      If your Kollmorgen Servo Drives feels too soft, it could be because the Kp (speed controller) is too low, Tn (speed controller) is too high, or ARLPF/ARHPF or ARLP2 are too high. Increase Kp (speed controller), use the motor default value for Tn (speed controller), and reduce ARLPF/ARHPF and ARLP2.
  • S
    Steven WhiteSep 1, 2025
    How to fix Kollmorgen Servo Drives motor oscillations?
    • B
      Bryan SanchezSep 1, 2025
      If your Kollmorgen Servo Drives motor oscillates, it could be due to several reasons. The gain might be too high, so try reducing Kp (speed controller). Check if the shielding in the feedback cable is broken and replace the cable if necessary. Ensure that AGND is properly wired up by joining it to CNC-GND.

Kollmorgen S70601-SE Specifications

General IconGeneral
SeriesS700
Input Voltage24 - 48 VDC
Continuous Output Current6 A
Peak Output Current12 A
Number of Axes1
Communication InterfaceEtherCAT
Peak Current12 A
Continuous Power Dissipation60 W
Protection ClassIP20
Operating Temperature0°C to +40°C