Kollmorgen S700 Series - User Manual

Kollmorgen S700 Series
166 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
S700
Digital Servo Amplifier S748x2...S772x2 (STO dual channel)
Instructions Manual
Edition: July 2019,
Translation of the original document
Valid for Hardware Revision 02.30
For safe and proper use, follow
these instructions.
Keep them for future reference.

Table of Contents

Other manuals for Kollmorgen S700 Series

Questions and Answers

  • C
    Connor BakerSep 18, 2025
    Why does my Kollmorgen Servo Drives axis drifts at setpoint = 0V?
    • W
      wmirandaSep 18, 2025
      If your Kollmorgen Servo Drives axis drifts at a setpoint of 0V, it could be because the offset is not correctly adjusted for analog setpoint provision; adjust the offset (analog I/O). Another potential cause is that AGND is not joined to the controller-GND of the controls; join AGND and controller-GND.
  • D
    Derrick KellerAug 25, 2025
    How to solve communication fault HMI message on Kollmorgen Servo Drives?
    • K
      Kevin MccormickAug 25, 2025
      A communication fault HMI message on Kollmorgen Servo Drives can be caused by using the wrong cable, plugging the cable into the wrong position on the servo amplifier or PC, or selecting the wrong PC interface. Use a null-modem cable, plug the cable into the correct sockets on both the servo amplifier and PC, and select the correct interface to resolve this issue.
  • B
    brandon35Aug 25, 2025
    What to do if my Kollmorgen Amplifier drive reports a following error?
    • J
      Joseph HoffmanAug 26, 2025
      If your Kollmorgen Amplifier drive reports a following error, it could be due to the current settings being too low or the setpoint ramp being too long. Try increasing the current settings, but stay within the motor limits, or shorten the setpoint ramp.
  • G
    Gina McdanielAug 26, 2025
    How to fix Kollmorgen S700 Amplifier communication fault?
    • O
      oruizAug 27, 2025
      To resolve a communication fault HMI message on your Kollmorgen Amplifier, ensure you are using the correct null-modem cable and that the cable is plugged into the correct sockets on both the servo amplifier and the PC. Also, verify that the correct PC interface is selected.
  • O
    ovincentSep 18, 2025
    What to do if my Kollmorgen Amplifier motor does not rotate?
    • L
      Lindsey RobinsonSep 18, 2025
      If the motor does not rotate, several factors could be at play. First, ensure the servo amplifier is enabled by applying the ENABLE signal and setting the software enable. Check the setpoint cable for any breaks and correct the motor phase sequence if the phases are swapped. Also, verify the brake control to ensure the brake is released and inspect the mechanism for any mechanical blockages. Confirm that the motor pole number is set correctly and that the feedback is properly configured.
  • J
    jennifershawSep 23, 2025
    What to do if Kollmorgen Amplifier axis drifts at setpoint = 0V?
    • R
      rsmithSep 23, 2025
      If the axis drifts when the setpoint is at 0V, it might be due to an incorrectly adjusted offset for the analog setpoint provision; in this case, adjust the offset (analog I/O). Another potential cause is AGND not being joined to the controller-GND of the controls; connect AGND and controller-GND.
  • E
    Eric JohnsonSep 9, 2025
    Why does my Kollmorgen S700 drive feel too soft?
    • K
      Karen CarlsonSep 9, 2025
      If the Kollmorgen Amplifier drive is too soft, the gain might be too low, or other settings might be incorrect. Try increasing the gain and using the motor's default value. Reduce the ARLPF / ARHPF and reduce ARLP2.
  • W
    williamgallowaySep 10, 2025
    Why does my Kollmorgen Amplifier drive run roughly?
    • D
      Douglas VelezSep 10, 2025
      If the Kollmorgen Amplifier drive runs roughly, it could be due to incorrect gain settings. Try reducing the gain and using the motor's default value. Increase the ARLPF / ARHPF and increase ARLP2.
  • C
    caroldaySep 3, 2025
    Why is my Kollmorgen Servo Drives too soft?
    • M
      Michael RichardsSep 3, 2025
      If your Kollmorgen Servo Drives feels too soft, it could be because the Kp (speed controller) is too low, Tn (speed controller) is too high, or ARLPF/ARHPF or ARLP2 are too high. Increase Kp (speed controller), use the motor default value for Tn (speed controller), and reduce ARLPF/ARHPF and ARLP2.
  • F
    Franklin RussellSep 1, 2025
    How to fix Kollmorgen Servo Drives motor oscillations?
    • C
      catherinerichmondSep 1, 2025
      If your Kollmorgen Servo Drives motor oscillates, it could be due to several reasons. The gain might be too high, so try reducing Kp (speed controller). Check if the shielding in the feedback cable is broken and replace the cable if necessary. Ensure that AGND is properly wired up by joining it to CNC-GND.

Summary

Safety

You should pay attention to this

Emphasizes critical safety aspects requiring specialist knowledge and documentation review.

Use as Directed

Specifies intended applications and conditions for the servo amplifiers.

Technical description

Technical data

Presents electrical and mechanical data, including ratings and specifications.

Safety function STO

Details the Safe Torque Off (STO) function, its advantages, and safety levels.

Mechanical Installation

Electrical Installation

Feedback systems

Introduces the importance and types of feedback systems used with servo drives.

Setup

Setup software

Describes the DRIVEGUI.EXE software for amplifier configuration and control.

Quickstart, initial drive test

Provides a simplified guide for initial setup and basic drive testing.

Trouble shooting

Provides solutions for common faults and operational problems.

Expansions

Expansion card Safety 2-2 (S4)

Details the Safety 2-2 expansion card for safe drive functions, including STO, SS1, SS2.

Kollmorgen S700 Series Specifications

General IconGeneral
Control ModesVelocity, Position
Feedback OptionsResolver
Communication InterfacesEtherCAT, CANopen
Safety FeaturesSTO (Safe Torque Off), SS1 (Safe Stop 1)
Protection FeaturesOvercurrent, Overvoltage, Overtemperature, Short Circuit
Operating Temperature Range0°C to +40°C
Humidity5% to 95% non-condensing
DimensionsVaries by model
WeightVaries by model