EasyManua.ls Logo

Kolver EDU 2AE/TOP/TA - Sequence Menu; Sequence Set; Sequence; External Box

Kolver EDU 2AE/TOP/TA
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vers. 270921 Page 10
30) Starting Tor Starting torque: If T&A option is set on Tor mode (See T&A paragraph), you can
set the torque threshold the angle starts to be read from. When T&A is set on angle mode (see T&A
paragraph), you can set the torque threshold the angle starts to be carried out from.
In # mode, the torque threshold must be included in the range of values relating to the pre-set speed and
model.
31) Ang. minMinimum angle: Minimum angle threshold. You can set it when T&A is set on Tor, T/in
or T/lv (see T&A specific instructions). The minimum angle the operator can set is 5°.
-
-
-
-
-
ME
N
U
-
-
P
R
:
1
-
-
-
-
-
3
1
)
A
n
g
.
m
i
n
:
-
-
-
-
3
2
)
A
n
g
.
m
a
x
:
-
-
-
-
32) Ang. max - Maximum angle: Maximum angle threshold. You can set it when T&A is set on Tor,
T/in or T/lv (see T&A specific instructions). The maximum angle the operator can set is 29999°.
When T&A is set on Ang., A/in or A/lv mode, maximum angle corresponds to the angle that has to be
carried out.
SEQUENCE MENU:
-
-
-
S
E
Q
U
E
N
C
E
-
M
E
N
U
-
-
-
-
O
K
c
h
a
n
g
e
E
S
C
q
u
i
t
1
)
S
e
q
s
e
t
:
1
4
7
3
9
8
1
2
2
)
S
e
q
u
e
n
c
e
:
o
f
f
1) Seq set: you can set a sequence up to max. 8 programs.
To set the next program in the sequence, press OK.
Press to save the sequence and quit.
To set the programs of a sequence, it is suggested to set the Model Detect in Manual and manually select the
desired screwdriver model for each program. Then enable automatic recognition. If you select a program
which does not have a screwdriver model set (----), the Select model warning will appear and this setting
will be exited.
2) Sequence: to enable or disable the sequence. ON = enabled; OFF = disabled.
-
-
-
S
E
Q
U
E
N
C
E
-
M
E
N
U
-
-
-
-
3
)
E
x
t
b
o
x
:
o
f
f
4
)
M
o
d
.
b
a
r
c
:
o
f
f
5
)
I
n
s
.
b
a
r
c
o
d
e
S
e
q
3) Ext box: It allows to enable or disable the external control.
IMPORTANT: It is mandatory to select ON to work with switch box, socket tray and remote.
4) Barc. mode: – Barcode mode: It allows to choose the barcode mode.
OFF: barcode disabled.
ON prog: you can select the program to be executed by scanning the bar code of the product. The
unit compares the scanned code to the one previously entered in each program (see point 27: Barc.
Set.). If the two codes match, the program is loaded; otherwise it will display Error Barcode. The

Related product manuals