6.7 Balance measurement in elevators with V
3
F25 drive
Step Action Note
1 Measure the voltage between MEAS
test point and AGND on HCB board.
This voltage is equivalent to the motor
current.
Measuring points on HCB board:
2 Drive the empty car downwards and
with rated load upwards.
Use rated speed.
Measure these values at same level in
the elevator shaft.
3 Record values. The difference of the measurements
may be about 5 %.
4 If the difference is more than 5 %, recheck the elevator mechanical balancing.
Check also the adjustment of guide shoes or rollers against the guide.