V3F25/18 drive
Installation Instruction
© 2004 KONE Corporation AM-11.65.020
All rights reserved. 24 (42) (E) 2004-01-08
5.2 Repeating the resolver angle setting
Repeat the resolver angle setting when the ropes are installed.
This must be done before shaft setup.
Refer to Initial setting of the resolver angle.
5.3 Shaft setup
Step Action Note
1 Ensure that the elevator is in RDF mode (machine room inspection drive mode in
North America).
2 Drive the car just below the bottom floor.
3 Check that the LEDs 61:U, 77:N and
77:S light.
LED 61:N must not light. LCE LEDs 30
and/or B30 must light.
4 Activate the setup mode from the
controller.
Set
Shaft setup (5_2) parameter to 1.
The buzzer on the HCB board starts to
sound: long beeps with some delay.
[ ___ ]
5 Turn the RDF (machine room
inspection drive in North America) to
normal.
Elevator starts the setup drive upwards.
6 Follow the setup drive steps on the user
interface.
Elevator is ready for the normal drive
when the elevator stops at the topmost
floor and the user interface shows the
number of the topmost floor.