130 Part Number STH063 9/17

NOTE: These characteristics may vary depending on
operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser

Freeze Time Harvest
Time

  
 9.8-11.2 10.2-14.8 10.6-12.1
1.0-2.5
 10.0-11.4 10.6-12.1 11.5-13.1
 10.7-12.2 11.9-13.5 13.4-15.2
 12.3-13.9 12.6-14.3 14.5-16.4
 12.6-14.3 13.6-15.4 15.2-17.2
Times in minutes
24 Hour Ice Production
Air Temp. Entering


  

 1650 1565 1460
 1560 1480 1370
 1470 1420 1280
 1380 1345 1190
 1345 1260 1140
Based on average ice slab weight of 13.20 - 14.80 lb (5.99 – 6.71 kg)
230/50/1 production is approximately 12% lower than 230/60/1.
Operating Pressures
Air Temp.
Entering
Condenser

Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
 270-285 60-38 170-190 120-135
 300-320 60-38 180-210 130-140
 300-340 60-39 180-210 130-140
 310-380 70-40 180-210 130-140
 380-460 80-41 200-210 135-150
 400-480 85-42 210-220 140-155
Suction pressure drops gradually throughout the freeze cycle