Push [ENTER] and advance it to the following inspection.
14-5 Touch pannel calibration
Note) Do the calibration since Ver1.5.1
according to the description of b).
a) Touch center of “+” by using stylus pen.
The square around "+" becomes green from
red.
After the calibration, push [ENTER] and
advance it to the following inspection.
b)Since Ver1.5.1
and are displayed on the LCD screen as shown in the following photograph.
Do the calibration according to the procedure for showing in the following b1, b2, and b3
with a stylus.
b1. Touch cross point of or internal of displayed in a red square (1).
The value of “Saved Value =” in the LCD display is updated at the same time as touching.
(note) The value of the position in which it touched first is used for the calibration.
The value is not used even if it moves after it touches.
When the calibration is done over again, you should separate the stylus from the
screen once.
And, the value is updated when touching.
b2. and are displayed on the red square (2).