EasyManua.ls Logo

Kramer KDS-7-MNGR - Page 70

Kramer KDS-7-MNGR
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Kramer Electronics Ltd.
KDS-7-MNGR Protocol 3000
68
Function
Description
Syntax
Response
Parameters/
Attributes
Example
KDS-ROUTE?
Get the route
relationship between
encoder and
decoders with
specific signal type.
#KDS-ROUTE? <signal_type><CR>
~nn@KDS-ROUTE
<signal_type>,[<encoder_device
_id>,<decoder_device_id>,<dec
oder_device_id>,...],[...]...<CR><
LF>
<signal_type> - Video,
audio, usb, ir, rs232, cec,
all
<encoder_device_id> -
Device id of encoder
<encoder_device_id> -
Device id of decoder
Get the video route from the encoders
decoders in the system:
#KDS-ROUTE? video
LOCK-FP
Lock the front panel.
#LOCK-FP <lock_mode><CR>
~nn@LOCK-FP
<lock_mode><CR><LF>
<lock_mode> -
0 - Off
1 - On
Set lock front panel to on:
#LOCK-FP 1
LOCK-FP?
Get the front panel
lock state.
#LOCK-FP?<CR>
~nn@LOCK-FP
<lock_mode><CR><LF>
<lock_mode> -
0 - Off
1 - On
Get lock front panel status:
#LOCK-FP?
LOG-ACTION
Set event log
configuration.
#LOG-ACTION
<action>,<period><CR>
~nn@LOG-ACTION
<action>,<period><CR><LF>
<action> -
1 - Start, start logging
2 - Pause, pause
logging but keep log
content
3 - Resume, resume
the logging
4 - Reset, clear all
current logs, keep logging
<period> - Relevant for
"start"
1 - Keep current
2 - Daily
3 - Weekly ( default)
Set the events log state:
#LOG-ACTION 1,3
LOG-ACTION?
Get events log
configuration.
#LOG-ACTION?<CR>
~nn@LOG-ACTION
<action>,<period><CR><LF>
<action> - One of
1 - Start, start logging
2 - Pause, pause
logging but keep log
content
3 - Resume, resume
the logging
4 - Reset, clear all
current logs, keep logging
<period> - Relevant for
"start"
1 - Keep current
2 - Daily
3 - Weekly ( default)
Get the events log state:
#LOG-ACTION?
LOGIN
Set protocol
permission.
+ The permission
system works only if
security is enabled
with the “SECUR”
command.
+ LOGIN allows the
user to run
commands with an
End User or
Administrator
permission level.
+ When the
permission system is
enabled, LOGIN
enables running
commands with the
User or Administrator
permission level
When set, login must
be performed upon
each connection
+ It is not mandatory
to enable the
permission system in
order to use the
device
+ In each device,
some connections
allow logging in to
different levels.
Some do not work
with security at all.
Connection may
logout after timeout.
#LOGIN <user_name>,<password>
~nn@LOGIN
<user_name>,<password>
<user_name> - User
name
<password> - Password
Login:
#LOGIN admin,admin
LOGIN?
Get current protocol
permission level.
#LOGIN?<CR>
~nn@LOGIN <role><CR><LF>
<role> - Level of current
permissions
Administrator
Configurator
Operator
Get login state:
#LOGIN?
LOGOUT-
TIMEOUT
Set Inactivity auto-
logout time in
minutes
#LOGOUT-TIMEOUT <time><CR>
~nn@LOGOUT-TIMEOUT
<time><CR><LF>
<time> - Minutes of logout
time
Set log out time to 10 minutes:
#LOGOUT-TIMEOUT 10
LOGOUT-
TIMEOUT?
Get Inactivity auto-
logout time in
minutes
#LOGOUT-TIMEOUT?<CR>
~nn@LOGOUT-TIMEOUT
<time><CR><LF>
<time> - Minutes of logout
time
Get logout time:
#LOGOUT-TIMEOUT?
MODEL?
Get device model.
#MODEL?<CR>
~nn@MODEL
<model_name><CR><LF>
<model_name> - Model
name
Get device model:
#MODEL?