Magnetisch-induktives Durchflussmessgerät
Electromagnetic flowmeter
Débitmètre électromagnétique
80290424
© KROHNE 09/2020 - 4007608302 - QS AF-E 400 R02 en-de-fr
AF-E 400
Quick Start

Other manuals for KROHNE AF-E 400

Questions and Answers

  • G
    ghernandezSep 10, 2025
    How to unlock setting buttons on KROHNE AF-E 400 Measuring Instruments unit?
    • B
      Brian ThompsonSep 10, 2025
      If the setting buttons on the unit are locked, and parameter change is rejected, unlock the unit.
  • A
    Anthony GordonSep 12, 2025
    What to do if parameter setting is locked via push-buttons on KROHNE AF-E 400?
    • E
      Evan WestSep 12, 2025
      If parameter setting is locked via push-buttons and active via IO-Link communication, finish parameter setting via IO-Link communication.
  • S
    Seth TorresSep 14, 2025
    How to unlock setting buttons locked via parameter setting software on KROHNE AF-E 400?
    • J
      Jimmy GarciaSep 14, 2025
      If the setting buttons are locked via parameter setting software and parameter change is rejected, unlock the unit via IO-Link interface using the parameter setting software.
  • T
    tracypooleSep 16, 2025
    How to deactivate IO-Link function on KROHNE AF-E 400 Measuring Instruments?
    • J
      Jennifer WilsonSep 16, 2025
      If the IO-Link function for optical identification of the unit is active, deactivate IO-Link function.

KROHNE AF-E 400 Specifications

General IconGeneral
TypeElectromagnetic flow meter
Nominal diameterDN 15 to DN 400
Housing materialStainless steel
Measuring PrincipleElectromagnetic
Operating pressureMax. 40 bar / 580 psi
Accuracy±0.2% of measured value ±1 mm/s
Lining materialPTFE
Electrode materialPlatinum
Protection classIP 67
Output4-20 mA, pulse output
CommunicationModbus
Power Supply24 V DC
MaterialStainless steel