GENERAL SAFETY INFORMATION 1
5
LT40 C/F
www.krohne.com10/2021 - 4009051601 - AD UKEX LT40 R01 en
1.4 Device categories
1.4.1 Ex ia-approved devices
The Ex ia-approved device has the marking that follows:
II 1 G Ex ia IIC T6...T1 Ga or II 2 G Ex ia IIC T6...T1 Gb
The Ex ia-approved device is suitable for use in potentially explosive atmospheres of all
f
lam
mable substances in Gas Groups IIA, IIB and IIC. It is certified for applications requiring
EPL Ga or EPL Gb. It can be attached to the measuring chamber of a BM26A series bypass level
indicator that agrees with EPL Ga/Gb or EPL Gb, if the temperature limits are obeyed. For more
data, refer to
Operating conditions
on page 9.
1.4.2 Ex db-approved devices
The Ex db-approved device has the marking that follows:
II 2 G Ex db IIC T6...T1 Gb
The Ex db-approved device is suitable for use in potentially explosive atmospheres of all
f
lam
mable substances in Gas Groups IIA, IIB and IIC. It is certified for applications requiring
EPL Gb. It can be attached to the measuring chamber of a BM26A series bypass level indicator
that agrees with EPL Ga/Gb or EPL Gb, if the temperature limits are obeyed. For more data,
refe
r to
Operating conditions
on page 9.
INFORMATION!
This equipment can be installed in zone 0, 1 or 2.
INFORMATION!
This equipment can be installed in zone 1 or 2.

Related product manuals