TECHNICAL DATA
7
33
VA40 - VA45
www.krohne.com08/2015 - 4000424402 - MA VA40-45 R04 en
7.4 Measuring ranges
Measuring ranges VA40
Measuring span: 10 : 1
Declaration of flow: Values = 100% Water: 20°C [68°F] Air: 20°C [68°F], 1.013 bar abs. [14.7 psia]
Float materials: 1 Stainless Steel or Hastelloy® - 2 PTFE with insert - 3 TFM - 4 Aluminium - 5 Polypropylene (PP)
Materials → 1 2 3 1 3 4 5 1 2 3 4 5
Cone ↓ Water [l/h] Air [Nm3/h] Max. pressure loss [mbar]
G 13.11 1 DN15 0.4 - - 0.016 - 0.007 - 2 - - 1 -
G 14.06 0.63 - - 0.025 - 0.012 - 3 - - 2 -
G 14.08 1 - - 0.04 - 0.02 - 4 - - 3 -
G 15.07 1.6 - - 0.06 - 0.03 - 4 - - 3 -
G 15.09 2.5 - - 0.09 - 0.04 - 5 - - 4 -
G 15.12 4 - - 0.14 - 0.06 - 6 - - 5 -
G 16.08 6.3 - - 0.2 - 0.1 - 6 - - 5 -
G 16.12 10 - - 0.3 - 0.16 - 7 - - 6 -
G 17.08 16 - - 0.5 - 0.25 - 7 - - 6 -
G 17.12 25 - - 0.8 - 0.4 - 8 - - 7 -
N 18.07 40 25 13 1.5 0.6 0.8 0.5 9 6 2 3 1
N 18.09 63 40 22 2.2 0.95 1.2 0.7 9 7 3 3 2
N 18.13 100 63 35 3 1.5 1.8 1.2 9 8 3 4 2
N 19.09 160 100 55 5 2.2 2.8 1.8 13 9 4 5 2
N 19.13 250 160 85 8 3.3 4.5 2.8 16 11 4 5 2
N 19.19 400 250 140 - - - - 21 14 5 7 3
N 19.26 630 400 230 - - - - 27 17 6 10 4
N 21.09 DN25 630 400 230 18 2 9 11 7 22 14 6 8 3
N 21.13 1000 630 350 28 2 14 18 12 23 17 6 8 4
N 21.18 1600 1000 600 49 2 - 28 2 17 2 26 25 7 10 6
N 21.25 2500 1600 950 70 2 - 42 2 26 2 33 40 8 12 9
N 41.09 DN40 1600 1000 600 45 22 28 18 32 18 9 11 5
N 41.13 2500 1600 900 70 2 36 45 2 28 2 34 20 10 12 5
N 41.19 4000 2500 1500 128 2 - 76 2 46 2 38 24 11 15 8
N 51.10 DN50 4000 2500 1500 120 2 56 70 45 43 25 12 15 7
N 51.15 6300 4000 2400 190 2 90 110 2 70 2 47 30 13 16 7
N 51.21 10000 6300 3500 310 2 - 170 2 118 2 55 42 14 20 10
1 reduced accuracy 2.5%
2 only possible with guided float
INFORMATION!
The oper. press. should be at least twice the pressure loss for liquids, and at least 5
times the pressure loss for gases! The specified pressure drops are valid for water and air at maximum flow rate.
Other flow ranges on request. Conversion of other media or operating data (pressure, temperature, density,
viscosity) is performed using the calculation method in accordance with VDI /VDE Directive 3513