Special equipment
106
Pos: 37.37 /BA/So nderausstatung /EasyCut / AM M ähwerke/Qu erförderer/Hydra ulik Ölstands kontrolle Bild EC 2 800/2801 320 0/3201 3210/ 4013 @ 39\mod_ 12680422896 91_78.docx @ 3 57642 @ @ 1
Figure 68
Pos: 37.38 /Übersc hriften/Überschrif ten 3/K-O/Öl kontrolle @ 0\ mod_11970219 08190_78.doc x @ 16120 @ 2 @ 1
14.10.3 Checking the oil level
Pos: 37.39 /BA/So nderausstatung /EasyCut / AM M ähwerke/Qu erförderer/Hydra ulik-Ölstandsko ntrolle @ 10\ mod_1222335 584255_78.doc x @ 140585 @ @ 1
Check the hydraulic oil level after every 10 operating hours of the cross conveyor.
To do this:
• Lower the machine and switch off the engine.
• Unscrew and remove the ventilation filter (2) (with measuring rod).
• • Use a lint-free cloth to clean the ventilation filter (2) and insert it again completely.
• Pull out the ventilation filter (2) again.
• The oil level must lie between the min. and max. mark.
• Top off with hydraulic oil if necessary.
• Screw in and tighten the ventilation filter (2).
Pos: 37.40 /Übersc hriften/Überschrif ten 3/K-O/Öl wechsel @ 0\ mod_1197021 941955_78.doc x@ 16139 @ @ 1
14.10.4 Oil change
Pos: 37.41 /BA/So nderausstatung /EasyCut / AM M ähwerke/Qu erförderer/Hydra ulik-Ölwechsel @ 10\mod_1 22233596697 3_78.docx @ 1406 73 @ @ 1
Change the hydraulic oil every 500 hours (but at least once a year).
• Unscrew and remove the ventilation filter (2) (with measuring rod).
• Screw out the oil drain plug (3).
• Collect the used oil in a suitable drip pan.
• Screw in the oil drain plug (3).
• Top up oil (2) (the oil level must lie between the min. and max. mark).
• Screw in and tighten the ventilation filter (2).
Pos: 37.42 /BA/--- ------ ------Seitenumbruch---- ------------ @ 0\m od_1196175311 226_0.docx @ 4 165 @ @ 1