5 Installation at Site
19 of 48
KSB Delta Basic
1983.835/01-EN
5 Installation at Site
5.1 Checks to be carried out prior to installation
WARNING
Installation on mounting surfaces which are unsecured and cannot support the
load
Personal injury and damage to property!
▷ Use a concrete of compressive strength class C12/15 which meets the
requirements of exposure class X0 to EN206-1.
▷ The mounting surface must have set and must be completely horizontal and
even.
▷ Observe the weights indicated.
NOTE
The anti-vibration mounts of the pressure booster system provide adequate
insulation against solid-borne noise.
Thanks to level-adjustable feet (KSB accessory) the pressure booster system can also
be installed in a horizontal position on uneven floors.
For pressure booster systems with pumps, Movitec 2, 4, 6, 10, 15 level-adjustable feet
are available as accessories.
NOTE
Do not install pressure booster systems next to sleeping or living quarters.
NOTE
The installation room must provide for suitable drainage.
Before beginning with the installation check the following:
▪ All structural work required has been checked and prepared in accordance with
the dimensions in the outline drawing.
▪ The pressure booster system can be operated on the power supply network
according to the data on the name plate.
▪ The place of installation is frost-free.
▪ The place of installation can be locked.
▪ The place of installation is well-ventilated.
▪ A suitably dimensioned drain connection (e.g. leading to a sewer) is available.
▪ If expansion joints are used, take note of their creep resistance. Expansion joints
must be easily replaceable.
5.2 Installing the pressure booster system
WARNING
Top-heavy pressure booster system
Risk of personal injury by pressure booster system tipping over!
▷ Pressure booster systems awaiting final installation must be secured against
tipping over.
▷ Firmly anchor the pressure booster system.