CAUTION
Motor and pump running in the wrong direction of rotation
Damage to the pump!
▷ Refer to the arrow indicating the direction of rotation on the pump.
▷ Check the direction of rotation. If required, interchange any two phases to
correct the direction of rotation.
The correct direction of rotation of motor and pump is clockwise (seen from the
motor end).
1.
Start the pump set and stop it again immediately to determine the motor's
direction of rotation.
2. Check the direction of rotation.
The motor's direction of rotation must match the arrow indicating the direction
of rotation on the pump.
3. If the pump runs in the wrong direction of rotation, check the electrical
connection of the motor and the control system, if necessary.
5 Installation at Site
KWP
37 of 78