EasyManuals Logo

KSB KWP User Manual

KSB KWP
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
A B C D E F G H Possible cause
Remedy
22)
X Tie bolts/gasket defective. Fit new seal between volute casing and
discharge cover.
Re-tighten the bolts.
X Worn shaft seal. Fit new shaft seal.
X X Score marks or roughness on shaft
protecting sleeve / shaft sleeve
Replace shaft protecting sleeve / shaft sleeve.
Fit new shaft seal.
Check the balancing line.
Check throttling bush / throttle sleeve
clearances.
X Lack of cooling liquid or dirty cooling
chamber.
Increase cooling liquid quantity.
Clean out cooling chamber.
Purify/clean cooling liquid.
X X Gland follower too tight or askew. Correct.
X X Pump back pressure is lower than
specified in the purchase order.
Adjust duty point accurately.
X Vibrations during pump operation Correct suction conditions.
Re-align the pump set.
Re-balance the impeller.
Increase pressure at the pump suction nozzle.
X X X The pump set is misaligned. Re-align the pump set.
X Insufficient or excessive quantity of
lubricant or unsuitable lubricant.
Top up, reduce or change lubricant.
X Non-compliance with specified coupling
distance.
Correct distance according to the general
arrangement drawing.
X Operating voltage is too low. Increase voltage.
Check voltage drop in the power supply
cable.
X Rotor is out of balance. Clean impeller.
Re-balance impeller.
22)
Pump pressure must be released before attempting to remedy faults on parts which are subjected to pressure.
8 Trouble-shooting
70 of 78
KWP

Table of Contents

Other manuals for KSB KWP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KSB KWP and is the answer not in the manual?

KSB KWP Specifications

General IconGeneral
BrandKSB
ModelKWP
CategoryWater Pump
LanguageEnglish

Related product manuals