OPERATION AND INSTALLATION MANUAL
COD. 091114 COMPACK 2 ECO / SPECIAL - REV. 08 - DATE 10/2020 page 30 of 63
7.6.2.2 GROUND CONNECTION
The compressor must be connected to the ground during its use, in order to protect the operator
from accidental electric shocks. It’s necessary that the connections are made by a technician or an
authorized service center. The grounding conductor yellow / green wire of the power of the
compressor must only be connected to terminal of the compressor.
The ground wire connected to a facility must be properly equipped with mandatory safety switch.
7.6.2.3 SIZING OF ELECTRIC CABLE
Do not use a damaged cable but make sure it is in good condition. This section must be appropriate
to the current requested by the compressor. A little section of power cable can cause a voltage drop
with consequent loss of power and excessive heating of the cable itself, which can cause irreparable
consequences on the device supply. The cable section must be in proportion to its length. For
variations and modifications contact a qualified service centre.
Avoid any risk of electric shock. Never use the compressor with a damaged power
cable. It is recommended to be checked periodically by a qualified power cords. Never
use the compressor in areas where they can be hazardous leakage current.
All electrical installations and maintenance on facility must be performed by a
qualified technician.
kW
SIZING
2,7 - 230V/ 1ph /50-60 Hz
2,5 mm²
3 400-460V / 3ph /50-60 Hz
1,5 mm²