45PERIODIC SERVICE
A When using the auxiliary hydraulics, replace the filter
cartridge after initial 50 service hours of operation.
BCleaning Transmission Strainer
When changing the transmission fluid, remove and clean
completely the oil strainers with kerosene. Be careful not
to damage the strainer parts when installing.
A As the fine filings in the oil could injure the component
parts of the hydraulic system precision built to
withstand high pressure, the suction line end is
provided with an oil strainer.
BChecking Radiator Hose and Clamp
Check to see if radiator hoses are properly fixed every 200
hours of operation or six months, whichever comes first.
1. If hose clamps are loose or water leaks, tighten clamps
securely.
2. Replace hoses and tighten hose clamps securely, if
radiator hoses are swollen, hardened or cracked.
BChanging Rear Axle Differential Case
Fluid
(See "LUBRICANTS, FUEL AND COOLANT" in
"MAINTENANCE" section.)
Remove the drain and filling port plug. After draining,
replace the drain plug and fill with new oil.
(1) Strainer
(1) Strainer
(2) O ring
(3) Suction pipe
(1) Radiator core
(2) Radiator hose
Oil capacity 1.5 L (1.6 U.S.qts.)
(1) Filling plug with dipstick
(2) Drain plug
(A) Oil level is acceptable within
the range